Why there is no "normal" number here
Almost every HOMA-IR calculator online will hand you a number and a verdict. The verdict is the part that isn't supported. There is no universally accepted cutoff for HOMA-IR. Thresholds in common use in the US fall somewhere between 2.0 and 3.0 — NHANES uses 2.5 — while cut points reported in Asian populations run lower. The score also isn't attached to any validated treatment algorithm: no guideline says "at this number, do this."
That doesn't make it useless. It makes it a trend instrument rather than a verdict machine. Your own HOMA-IR measured the same way, in the same lab, six months apart, is a far more informative number than your HOMA-IR compared to a threshold from a study population you may not resemble.
Getting the inputs right
- Both samples must be fasting, and from the same draw. Pairing a fasting glucose with an insulin taken at a different visit produces a number that means nothing.
- Insulin assays are not standardised between labs. Two labs can return different insulin values for the same blood. This is the main reason to compare your score only against your own previous scores, from the same lab.
- Many standard panels don't include fasting insulin. You usually have to ask for it specifically — it isn't part of a routine lipid or metabolic panel.
- If you take insulin, HOMA-IR doesn't apply. The model assumes your own pancreas produced the insulin being measured.
What the number is made of
| Units | Formula |
|---|---|
| Glucose mg/dL | (fasting glucose × fasting insulin) ÷ 405 |
| Glucose mmol/L | (fasting glucose × fasting insulin) ÷ 22.5 |
Insulin is in µIU/mL in both (sometimes written mIU/L — the same thing). If your lab reports insulin in pmol/L, this page divides by 6.0 to convert. The model was scaled so a healthy young adult sits near 1.
What moves it is what moves insulin sensitivity generally: sleep, muscle, movement after meals and what the meal was made of. If you want the graded evidence on each of those rather than claims, the Evidence Library is the honest version.